We are using the thrie beam transition to rigid barrier developed in TRP-03-210-10.    This transition was crash tested without a curb under it.  Some other thrie beam transitions that MwRSF has crash tested used a sloped 4-inch curb.

 

Is it possible to use a 4" sloped curb similar to the previous crash tests with the transition in TRP-03-210-10?

Keywords
  • Approach Guardrail Transitions
  • Guardrail
Other Keywords none
Date June 30, 2011


Response
Response

I am assuming that you are referring to the curb detailed in TRP-03-69-98.  If so, I do not believe that the addition of the 4" sloped curb would cause any adverse effects.  However, be sure to use the same geometry for the curb, i.e., the height, slope, and length of the curb should not exceed that dimensions illustrated in the noted report.  Note, this will keep your curb downstream of the asymmetrical transition piece and within the thrie beam rail sections for the newer transition.  Further, the lateral placement of the curb must be as detailed in the original report (with the back of the curb adjacent to the face of the post).

Date July 5, 2011


Contact Us:
130 Whittier Research Center
2200 Vine Street
Lincoln, NE 68583-0853
(402) 472-0965
Email: mwrsf@unl.edu
Disclaimer:
The information contained on the Midwest Roadside Safety Facility (MwRSF) website is subject to change without prior notice. The University of Nebraska and the MwRSF is not responsible or liable, directly or indirectly, for any damage or loss caused or alleged to be caused by or in connection with the use or misuse of or reliance upon any such content, goods, or services available on this site.