Logged in as: Public User

TRP-03-277-14

Question
State WI
Description Text

Can I get the CADD for the hardware in TRP-03-277-14


The box that we are planning to attach to had some concrete surface issues.  Is it possible to increase the embedment of the connection to account for concrete surface issues?

Keywords
  • Bridge Rails
  • Guardrail
Other Keywords embedment
Date January 14, 2016


Response
Response I have attached a ZIP file containing CADD file of the final system drawings.

If your culvert has concrete surface damage, increase the embedment depth of the anchor rods by the depth of the surface damage:

New EMB = Design EMB + Surface Damage Depth.
Date January 22, 2016
Attachment CAD for MGS Attached to Culvert.zip


Contact Us:
130 Whittier Research Center
2200 Vine Street
Lincoln, NE 68583-0853
(402) 472-0965
Email: mwrsf@unl.edu
Disclaimer:
The information contained on the Midwest Roadside Safety Facility (MwRSF) website is subject to change without prior notice. The University of Nebraska and the MwRSF is not responsible or liable, directly or indirectly, for any damage or loss caused or alleged to be caused by or in connection with the use or misuse of or reliance upon any such content, goods, or services available on this site.